Hammerset anchor E, steel, galvanised
Hammerset anchor E steel, zinc-plated, M 16x65
For non-cracked concrete and for attaching multiple non-load-bearing systems to cracked concrete






Register now and access more than 10,000 products
For non-cracked concrete and for attaching multiple non-load-bearing systems to cracked concrete
The hammerset anchor E is a drop-in anchor for anchoring in concrete.
The anchor is set into the drill hole in cotter-pin installation and reliably expanded using a manual or mechanical spreading tool and can be loaded straight away. The mounting can easily be loosened again.
No need for installation torque.
Application area:
Suspended items in heating, sanitation and ventilation, anchoring with threaded rods and bolts, flat steel and profiled steel.
Advantages:
- Approved for multiple attachment in cracked and non-cracked concrete
- Approved for multiple attachment in hollow pre-stressed concrete plate ceilings
- Approved for use as a single anchor for fixing in non-cracked concrete (anchoring depth ≥ 30 mm)
- Low drilling depth means a low risk of hitting reinforcements (anchoring depth 25 mm)
- Stop bit and SDS plus mechanical setting tool ensure fast, efficient and labour-saving assembly
- The marker setting tool makes visual installation checks easy
- Standard metric screws and threaded rods enable a wide range of applications
- FM approval for use in the installation of sprinkler systems (M10–M20)
- Suitable for use in the installation of sprinkler systems in accordance with the requirements of VdS Schadenverhütung GmbH (M8–M16)
- Fire-protection tested in concrete C20/25 to C50/60
Advice:
Fire protection tested in concrete C20/25 to C50/60.
Datasheets(X)
Type description | E M 16 |
Anchor diameter x anchor length (l) | 16 x 65 mm |
Nominal drill-bit diameter (d 0) | 20 mm |
Drill hole depth (h 0) | 65 mm |
Minimum component thickness (h min) | 160 mm |
Anchor length (l) | 65 mm |
Effective anchoring depth (h ef) | 65 mm |
Material | Steel |
Surface | Zinc plated |
Anchor diameter | 16 mm |
Min. edge clearance (c min) | 200 mm |
Min. centre-to-centre distance (s min) | 150 mm |
Through-hole in the component to be connected (d f) | 18 mm |
Torque during anchoring (T inst) | 60 Nm |
Select RAL-colour code
!! NOTE: On-screen visualisation of the colour differs from real colour shade!!